search-loading


VARYCONTROL


Air terminal units for supply or extract air for a variety of applications

Units of the VARYCONTROL types are air terminal units for supply and extract air systems. They can be used for almost any control, regulation and shut-off tasks in room air conditioning systems. The selection of the type of units is based on the acoustical requirements and the control functions.

Type TVZ · TVA

TVZ
  • Air terminal unit
  • Airtight shut-off
  • Flow rate control or duct or room pressure control
  • Electronic or pneumatic control components
  • Hygienically tested and certified according to VDI 6022


more details

circular, rectangular

15 – 1,680 l/s
54 – 6,048 m³/h
32 – 3,560 cfm
Δp: 20 – 1,500 Pa

Ø 125 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 125, class 3)

Type TVM

TVM
  • Dual duct air terminal unit
  • Airtight shut-off
  • Flow rate control
  • Electronic or pneumatic control components
  • Hygienically tested and certified according to VDI 6022


more details

circular, rectangular

45 – 1,680 l/s
162 – 6,048 m³/h
95 – 3,560 cfm
Δp: 150 – 1,500 Pa

Ø 125 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 125, class 3)

Type TVZ-Easy ·
TVA-Easy

TVZ-Easy
  • Easy - the innovative solution
  • Air terminal unit
  • Airtight shut-off
  • Flow rate control
  • Hygienically tested and certified according to VDI 6022


more details

circular, rectangular

15 – 1,675 l/s
54 – 6,030 m³/h
32 – 3,549 cfm
Δp: 20 – 1,000 Pa

Ø 125 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 125, class 3)

Type TVR

TVR
  • Circular vav controller
  • Airtight shut-off
  • Flow rate control or duct or room pressure control
  • Electronic or pneumatic control components


more details

circular

10 – 1,680 l/s
54 – 6,048 m³/h
21 – 3,560 cfm
Δp: 20 – 1,500 Pa

Ø 100 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 100 and 125, class 3)

Type TVJ · TVT

TVT
  • Rectangular vav controller
  • Airtight shut-off
  • Flow rate control or duct or room pressure control
  • Electronic or pneumatic control components


more details

square, rectangular

45 – 10,100 l/s
162 – 36,360 m³/h
95 – 21,401 cfm
Δp: 20 – 1,000 Pa

W: 200 – 1,000 mm
H: 100 – 1,000 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751,
TVT: class 4 (B < 600, class 3)
TVJ: class 1 (H = 100, class 0)

Type TVRK

TVRK
  • Circular plastic vav controller
  • Airtight shut-off
  • Flow rate control or duct or room pressure control
  • Electronic or pneumatic control components


more details

circular

30 – 1,025 l/s
108 – 3,690 m³/h
64 – 2,172 cfm
Δp: 20 – 1,500 Pa

Ø 125 – 315 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 125, class 3)

Type TVR-Easy

TVR-Easy 160
  • Easy - the innovative solution
  • Circular vav-controller
  • Airtight shut-off
  • Flow rate control


more details

circular

10 – 1,675 l/s
36 – 6,030 m³/h
23 – 3,549 cfm
Δp: 20 – 1,000 Pa

Ø 100 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751, class 4 (nominal size 100 and 125, class 3)

Type TVJ-Easy ·
TVT-Easy

TVJ EASY
  • Easy - the innovative solution
  • Rectangular vav-controller
  • Airtight shut-off (Not for TVJ)
  • Flow rate control


more details

square, rectangular

35 – 10,455 l/s
126 – 37,638 m³/h
74 – 22,153 cfm
Δp: 20 – 1,000 Pa

W: 200 – 1,000 mm
H: 100 – 1,000 mm

Casing air leakage flow rate complies with DIN EN 1751, class A
Control damper closed blade leakage complies with DIN EN 1751,
TVT-Easy: class 4 (B < 600, class 3)
TVJ-Easy: class 1 (H = 100, class 0)

AIRFLOW CONTROL

Professional Planning

With the design manual “AIRFLOW CONTROL” by TROX
Download

Installation Examples

Room air quality and economical operation
Control Units

Contact

TROX INDIA PRIVATE LIMITED

Unit No. 751,
5th Floor, Bldg. No. 7,
Solitaire Corporate Park,
Andheri (E), Mumbai-400093
Phone: +91 (0) 22 6775-1600
Contact and locations